NSN 5925-01-354-9719
Overload Switch
Multipole-multiple actuator type body style, plastic case material, 3 poles, maximum continuous load current rating per pole: 10.0 amperes ac all locations and 10.0 amperes dc all locations.
Manufacturer part number JA3S-A8-A-10-10 for national stock number 5925013549719.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-354-9719.
-
MPN or Model
JA3S-A8-A-10-10
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.3 lb -
Body Style
Multipole-multiple actuator type -
Body Length
2.000 inches -
Body Width
2.250 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.560 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Boss Height
0.130 inches -
Mounting Surface To Terminal End Distance
1.930 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
6 threaded hole -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations and 10.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations and 65.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations and 1000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
6.500 at 200 pct all locations and 45.000 at 200 pct all locations -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 quick disconnect, male
More from these suppliers
- 5925-00-450-5191 MPN 72-251-3MG6Circuit Breaker
- 5925-00-853-1995 MPN AM17MG3-15-120-54-400Circuit Breaker
- 5925-01-024-9567 MPN AM12MG6-3-208VAC400C14Circuit Breaker
- 5925-01-025-7007 MPN HB3Z1-91Circuit Breaker
- 5925-01-040-0434 MPN AM12-5-250-5-60Circuit Breaker
- 5925-01-041-3930 MPN HE1Z7-94Circuit Breaker
- 5925-01-130-7486 MPN AM33HKCircuit Breaker
- 5925-01-195-2303 MPN JA3-W3-A-20-2Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-354-9719 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
JA3S-A8-A-10-10 | Eaton Corp |
JA3S-A8-EB-01-D-A-10-1025 | Eaton Corp |
Stock Check
![](/public/images/partscage_shelf3.png)