NSN 5925-01-358-3118
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number T11-4-10.0A-06-11AV for national stock number 5925013583118.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-358-3118.
-
MPN or Model
T11-4-10.0A-06-11AV
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Bushing Length
Between 0.458 inches and 0.478 inches -
Body Length
Between 1.365 inches and 1.385 inches -
Body Width
Between 0.670 inches and 0.690 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.095 inches and 1.155 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
Between 1.685 inches and 1.745 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location and 10.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location and 32.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 1000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.500 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 at 200 pct single location and 15.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
General purpose -
Frequency In Hertz
50.0 single location or 60.0 single location -
Thread Series Designator
Un -
Terminal Type And Quantity
2 quick disconnect, male
More from these suppliers
- 5925-01-025-7007 MPN AP112-1-4-1-402Circuit Breaker
- 5925-01-046-6904 MPN AP-MIL-12-1R-7-2-203Circuit Breaker
- 5925-01-099-9539 MPN AP12-2508-4Circuit Breaker
- 5925-01-100-0970 MPN UPGH111-1ERC2-2630-6Circuit Breaker
- 5925-01-141-6683 MPN AP-12-1R-62F-1751Circuit Breaker
- 5925-01-148-1959 MPN 203-11-4691-1Circuit Breaker
- 5925-01-157-9950 MPN APG7-7332-3Circuit Breaker
- 5925-01-172-4571 MPN AP-112-4147-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-358-3118 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
T11-4-10.0A-06-11AV | Sensata Technologies Maryland, Inc |