NSN 5925-01-361-5509
Overload Switch
Poles seven,eight and nine have external actuator arrangement linkage. Pole eight also has an auxiliary switch.
Manufacturer part number APL-3REC4-24676-1 for national stock number 5925013615509.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-361-5509.
-
MPN or Model
APL-3REC4-24676-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Length
Between 2.480 inches and 2.500 inches -
Body Width
6.765 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.940 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.735 inches and 0.765 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.735 inches and 0.765 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.150 inches -
Mounting Surface To Terminal End Distance
2.625 inches -
Pole Quantity
9 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
18 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
9 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked and four, five, and six linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole two and internal at pole five -
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 at 200 pct all locations and 7.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Corrosion resistant and moisture resistant and shockproof and vibrationproof and fungus resistant -
Switch Terminal Type
Pin -
Switch Current Rating And Type In Amps
10.0 ac and 3.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Unpackaged Unit Weight
33.600 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
18 threaded stud
More from these suppliers
- 5925-00-118-1098 MPN AP2-1ACircuit Breaker
- 5925-00-142-0752 MPN APL1-55629-1-099Circuit Breaker
- 5925-00-320-6617 MPN APL11-1-4-2-203Circuit Breaker
- 5925-00-434-2038 MPN APL1-55629-1-026Circuit Breaker
- 5925-01-051-3694 MPN APL111-2387-19Circuit Breaker
- 5925-01-108-8048 MPN APL-1-6588-8Circuit Breaker
- 5925-01-141-6684 MPN AP-12-1R-62F-751Circuit Breaker
- 5925-01-208-1218 MPN AP112-9867-8Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-361-5509 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APL-3REC4-24676-1 | Sensata Technologies Maryland, Inc |