NSN 5925-01-377-1980
Overload Switch
Single pole type body style, plastic case material, 1 poles, maximum continuous load current rating per pole: 5.0 amperes dc single location.
Manufacturer part number 6508714-2 for national stock number 5925013771980.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-377-1980.
-
MPN or Model
6508714-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.2 lb -
Body Style
Single pole type -
Body Length
2.500 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
2.471 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 threaded hole -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.850 at 200 pct single location and 10.000 at 200 pct single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 4820-00-159-8558 MPN 820-2177957-1Seal Plate
- 4820-00-204-9595 MPN 5262928Plug Valve
- 5950-00-256-4933 MPN 6547387Power Transformer
- 4820-00-287-3897 MPN DE99S4200-121PC609Globe Valve
- 4820-00-852-5267 MPN AM351S4902-503287ALT1PC140Safety Relief Valve
- 5940-00-983-6056 MPN 1856938-15Terminal Board
- 4820-01-010-9066 MPN 820-4445829-32Special Cap
- 4820-01-046-4295 MPN 820-4384376-4Special Valve
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-377-1980 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
6508714-2 | Naval Sea Systems Command |
AM1-B2-A-5-2 | Eaton Corp |