NSN 5925-01-392-0878
Overload Switch
3 poles, 400.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts, maximum interrupting capacity current type and rating per pole in amps: 25000.0 ac all locations.
Manufacturer part number SGLA36AI0400 for national stock number 5925013920878.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-392-0878.
-
MPN or Model
SGLA36AI0400
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
12.1 lb -
Pole Quantity
3 -
Maximum Continuous Load Current Rating Per Pole
400.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
25000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Internal Trip Release Configuration
Series trip all locations -
Frequency In Hertz
60.0 all locations
More from these suppliers
- 5930-00-072-9278 MPN 7Knife Switch
- 5945-01-474-5957 MPN 139C4622G19Solid State Relay
- 5925-00-833-7947 MPN TE11030Circuit Breaker
- 5925-01-054-3248 MPN 193A1412-T053Circuit Breaker Tripper
- 5925-01-340-5538 MPN SELA36AT0100Circuit Breaker
- 5925-01-392-2832 MPN TB43250AF14Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-392-0878 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
SGLA36AI0400 | General Electric Co |
SGLA36A10400 | General Electric Co |
SGLA36A10400 | General Electric Co |
SGLA36A10400 | General Electric Co |
SGLA36AI0400 | General Electric Co |
SGLA36A10400 | General Electric Co |
SGLA36AI0400 | General Electric Co |
SGLA36A10400 | General Electric Co |
SGLA36AI0400 | General Electric Co |
SGLA36A10400 | General Electric Co |
SGLA36AI0400 | General Electric Co |
SGLA36A10400 | General Electric Co |
SGLA36AI0400 | General Electric Co |
SGLA36A10400 | General Electric Co |
SGLA36AI0400 | General Electric Co |
SGLA36A10400 | General Electric Co |
SGLA36AI0400 | General Electric Co |
SGLA36A10400 | General Electric Co |
SGLA36AI0400 | General Electric Co |
SGLA36A10400 | General Electric Co |
SGLA36AI0400 | General Electric Co |
SGLA36A10400 | General Electric Co |
SGLA36AI0400 | General Electric Co |
SGLA36A10400 | General Electric Co |