NSN 5925-01-392-9968
Overload Switch
Plastic case material, 2 poles, 30.0 amperes ac all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 250.0 ac all locations.
Manufacturer part number 3XC69 for national stock number 5925013929968.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-392-9968.
-
MPN or Model
3XC69
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.5 lb -
Case Material
Plastic -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Inclosure Protection Type For Which Designed
General purpose -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Terminal Type And Quantity
4 tab, solder lug
More from these suppliers
- 5945-01-314-9528 MPN 1A487-6Electromagnetic Relay
- 5940-01-631-1021 MPN 24C991Lug Terminal
- 6105-01-361-9247 MPN 5N256Alternating Current Motor
- 5925-01-250-3306 MPN AB3-B0-24-620-2B1-CCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-392-9968 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
3XC69 | W.w. Grainger, Inc. |
BA2-B0-34-630-111-D | Carling Technologies, Inc |
Stock Check
![](/public/images/partscage_shelf3.png)