NSN 5925-01-421-0661
Overload Switch
2 poles, 7.0 amperes ac all locations maximum continuous load current rating per pole, 240.0 ac all locations operating voltage type and rating per pole in volts, circuit protection type: overcurrent all locations.
Manufacturer part number AP-MIL-12-1-59-702 for national stock number 5925014210661.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-421-0661.
-
MPN or Model
AP-MIL-12-1-59-702
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Bushing Length
9.6 millimeters -
Center To Center Distance Between Terminals Parallel To Length
22.2 millimeters -
Mounting Surface To Terminal End Distance
45.2 millimeters -
Pole Quantity
2 -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Maximum Continuous Load Current Rating Per Pole
7.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Thread Size
0.375 inches -
Thread Series Designator
Unef -
Terminal Type And Quantity
4 wire hook
More from these suppliers
- 5925-00-520-7402 MPN APL11-1-61-153Circuit Breaker
- 5925-00-615-7989 MPN APL-1-1-52-123-MCircuit Breaker
- 5925-01-017-0133 MPN UPG1-12-6-2-752Circuit Breaker
- 5925-01-048-7480 MPN 203-1-1-42-252-1-1Circuit Breaker
- 5925-01-096-4685 MPN AP111-165-2Circuit Breaker
- 5925-01-138-4059 MPN T11-1-10.0A-02-31A-VCircuit Breaker
- 5925-01-213-4199 MPN UPG62-21159-1Circuit Breaker
- 5925-01-222-8168 MPN UPGH-66-1-62-502Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-421-0661 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AP-MIL-12-1-59-702 | Sensata Technologies Maryland, Inc |