NSN 5925-01-423-2752
Overload Switch
1 poles, 2.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts, circuit protection type: overcurrent single location.
Manufacturer part number PP11-61-2.00A-XXV for national stock number 5925014232752.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-423-2752.
-
MPN or Model
PP11-61-2.00A-XXV
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Pole Quantity
1 -
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Internal Trip Release Configuration
Series trip single location -
Trip Delay Time In Seconds Per Rated Continuous Current
0.100 at 200 pct single location and 2.000 at 200 pct single location -
Frequency In Hertz
50.0 single location or 60.0 single location
More from these suppliers
- 5925-00-403-6282 MPN APL111-609-111Circuit Breaker
- 5925-00-517-6816 MPN AP12-1R6-2-602Circuit Breaker
- 5925-01-087-9755 MPN AP112-1R-2943-2Circuit Breaker
- 5925-01-112-0320 MPN AP112-1R7-2F1752Circuit Breaker
- 5925-01-209-1824 MPN APGN-666-9094-3Circuit Breaker
- 5925-01-224-7030 MPN UPL1-1-42-202Circuit Breaker
- 5925-01-242-9944 MPN AP-17-1-71-202Circuit Breaker
- 5925-01-296-8293 MPN APL-11-1REC2-42F-501-MACircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-423-2752 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
PP11-61-2.00A-XXV | Sensata Technologies Maryland, Inc |