NSN 5925-01-424-1709
Overload Switch
Multipole-single actuator type body style, 2 poles, 10.0 amperes ac all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 240.0 ac all locations.
Manufacturer part number M39019/02-249S for national stock number 5925014241709.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-424-1709.
-
MPN or Model
M39019/02-249S
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Bushing Length
Between 0.332 inches and 0.380 inches -
Body Length
1.562 inches -
Body Width
1.281 inches -
Center To Center Distance Between Terminals Parallel To Length
0.610 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.360 inches and 0.390 inches -
Mounting Surface To Terminal End Distance
1.828 inches -
Pole Quantity
2 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Internal Trip Release Configuration
Series trip all locations -
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 at 200 pct all locations and 9.000 at 200 pct all locations -
Frequency In Hertz
60.0 all locations -
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Specification Data
81349--39019/03 government specification
More from these suppliers
- 5905-00-001-5837 MPN MILR55182-7Film Fixed Resistor
- 5905-00-001-7374 MPN RBR53L133R0BRNoninductive Wire Wound Fixed Resistor
- 5935-00-001-8826 MPN M81511-01C18-85P1Electrical Receptacle Connector
- 5905-00-004-0176 MPN RNR70C1301DSFilm Fixed Resistor
- 5905-00-004-5833 MPN RTR24DX201MNonprecision Wire Wound Variable Resistor
- 5905-00-004-6057 MPN MILR39009-1Inductive Wire Wound Fixed Resistor
- 5905-00-004-6058 MPN RER65F4R87MInductive Wire Wound Fixed Resistor
- 5905-00-004-6078 MPN RNC60H1022FPFilm Fixed Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-424-1709 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M39019/02-249S | Military Specifications |
MIL-C-39019/3 | Military Specifications |
M39019/02-249S | Military Specifications |
MIL-C-39019/3 | Military Specifications |