NSN 5925-01-424-2425
Overload Switch
Single pole type body style, metal case material, 1 poles, maximum continuous load current rating per pole: 5.0 amperes dc single location.
Manufacturer part number 6510-002-5 for national stock number 5925014242425.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-424-2425.
-
MPN or Model
6510-002-5
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1 lb -
Body Style
Single pole type -
Overall Length
3.250 inches -
Body Width
1.200 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
Unthreaded Mounting Hole Diameter
0.172 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.940 inches -
Mounting Surface To Terminal End Distance
4.260 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location and 115.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3600.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
200.0 single location -
Reset Method
Automatic -
Internal Trip Release Configuration
Series trip single location -
Trip Delay Time In Seconds Per Rated Continuous Current
7.000 at 200 pct single location and 40.000 at 200 pct single location and 1.200 at 400 pct single location and 6.400 at 400 pct single location and 0.300 at 1000 pct single location and 1.200 at 1000 pct single location -
Trip Release Ambient Tempurature Rating
-54.0 degrees celsius single location and 71.0 degrees celsius single location -
Frequency In Hertz
400.0 single location -
Test Data Document
81349-mil-c-83383 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). And 81349--83383/02 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Terminal Type And Quantity
2 threaded stud -
Specification Data
81349-mil-c-83383 government specification and 81349--83383/02 government specification
More from these suppliers
- 5925-01-049-3178 MPN 4001-002-1Circuit Breaker
- 5905-00-003-7718 MPN MILR55182-3Film Fixed Resistor
- 5905-00-004-6058 MPN RER65F4R87RInductive Wire Wound Fixed Resistor
- 5905-00-005-2668 MPN MILR39005-6Noninductive Wire Wound Fixed Resistor
- 5905-00-005-2689 MPN RNC50H5900FSFilm Fixed Resistor
- 5935-00-005-2821 MPN M83723/24R2410WElectrical Plug Connector
- 5905-00-007-3838 MPN RLR05C7502GRFilm Fixed Resistor
- 5935-00-009-6397 MPN M83723/76R22126Electrical Plug Connector
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-424-2425 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
6510-002-5 | Labinal, Llc |
M83383/02-01 | Military Specifications |
MIL-PRF-83383/2 | Military Specifications |
MIL-C-83383 | Military Specifications |