NSN 5925-01-429-0159
Overload Switch
Single pole type body style, metal case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number M39019/02-214 for national stock number 5925014290159.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-429-0159.
-
MPN or Model
M39019/02-214
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Thread Pitch Diameters
+0.3503/+0.3537 inches -
Body Style
Single pole type -
Bushing Length
0.380 inches -
Body Length
1.562 inches -
Body Width
0.625 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.906 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.700 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
0.75 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location and 50.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location and 500.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.375 inches -
Switch Location And Position Designation
Internal at pole one -
Inclosure Protection Type For Which Designed
Fungus resistant and dustproof -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc -
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc -
Frequency In Hertz
400.0 single location -
Test Data Document
81349-mil-prf-39019 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unef -
Terminal Type And Quantity
2 wire hook -
Specification Data
81349-mil-prf-39019/2 government specification
More from these suppliers
- 5905-00-001-2813 MPN RLR32C121JPFilm Fixed Resistor
- 5905-00-001-7186 MPN RP112FD501KKNonprecision Wire Wound Variable Resistor
- 5905-00-004-6034 MPN MILR39005-6Noninductive Wire Wound Fixed Resistor
- 5935-00-005-2859 MPN MILC83723-86Electrical Plug Connector
- 5905-00-005-2895 MPN RN70C1961FFilm Fixed Resistor
- 5905-00-005-9139 MPN MILR10509-2Film Fixed Resistor
- 5905-00-007-3895 MPN RBR55L42201BRNoninductive Wire Wound Fixed Resistor
- 5905-00-007-7144 MPN RBR71L17511AMNoninductive Wire Wound Fixed Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-429-0159 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M39019/02-214 | Military Specifications |
MIL-PRF-39019/2 | Military Specifications |
MIL-C-39019/2 | Military Specifications |
M39019/02-214 | Military Specifications |
MIL-PRF-39019/2 | Military Specifications |
MIL-C-39019/2 | Military Specifications |
M39019/02-214 | Military Specifications |
MIL-PRF-39019/2 | Military Specifications |
MIL-C-39019/2 | Military Specifications |
M39019/02-214 | Military Specifications |
MIL-PRF-39019/2 | Military Specifications |
MIL-C-39019/2 | Military Specifications |
M39019/02-214 | Military Specifications |
MIL-PRF-39019/2 | Military Specifications |
MIL-C-39019/2 | Military Specifications |
M39019/02-214 | Military Specifications |
MIL-PRF-39019/2 | Military Specifications |
MIL-C-39019/2 | Military Specifications |
M39019/02-214 | Military Specifications |
MIL-PRF-39019/2 | Military Specifications |
MIL-C-39019/2 | Military Specifications |