NSN 5925-01-452-8245
Overload Switch
Multipole-single actuator type body style, plastic case material, at 3 oclock and at 9 oclock nonturn device location, fragility factor: moderately rugged.
Manufacturer part number APGN-11-1REC4-61F-103 for national stock number 5925014528245.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-452-8245.
-
MPN or Model
APGN-11-1REC4-61F-103
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Bushing Length
0.625 inches -
Body Length
2.000 inches -
Body Width
1.500 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Nonturn Device Location
At 3 oclock and at 9 oclock -
Nonturn Device Radius
0.656 inches -
Nonturn Device Length
0.130 inches -
Nonturn Device Diameter
0.156 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
2.200 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.500 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 200 pct all locations and 70.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Dustproof and fungus proof -
Thread Series Designator
Un -
Terminal Type And Quantity
4 tab, solder lug
More from these suppliers
- 5945-00-791-4544 MPN 600Electronic Chopper
- 5925-00-192-0767 MPN AP12-206-1Circuit Breaker
- 5925-00-306-2822 MPN APL-111-1-42-353-MCircuit Breaker
- 5925-00-407-0789 MPN UPG111-1REC4-2630-5Circuit Breaker
- 5925-00-857-4850 MPN AP-1654-1Circuit Breaker
- 5925-01-059-9783 MPN AP-12-1-42F-302Circuit Breaker
- 5925-01-087-9755 MPN AP112-1R-2943-2Circuit Breaker
- 5925-01-104-4893 MPN UPL111-1-65-253MCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)