Datasheet
-
Product description
Circuit Breaker NSN 5925-01-458-0355.
-
MPN or Model
APL11-1-53F-403
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.6 lb -
Body Style
Multipole-single actuator type -
Body Length
2.490 inches -
Body Width
1.500 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.940 inches -
Center To Center Distance Between Terminals Parallel To Width
0.667 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.150 inches -
Mounting Surface To Terminal End Distance
1.850 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
40.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
Between pole one and two -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
16.500 at 200 pct all locations and 70.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
General purpose -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud
More from these suppliers
- 5945-00-751-0875 MPN 372Electronic Chopper
- 5925-00-320-6738 MPN APG1-1-4-1-251Circuit Breaker
- 5925-00-407-2184 MPN APL1R1195-18Circuit Breaker
- 5925-00-570-4771 MPN APL1-1R0-55629/2-128Circuit Breaker
- 5925-00-597-1267 MPN APL-111-1R0-55629/6-032Circuit Breaker
- 5925-01-070-9483 MPN AP112-R-020-235-0273Circuit Breaker
- 5925-01-150-0124 MPN APG-1-885-280Circuit Breaker
- 5925-01-162-4001 MPN T11-2-15.0A-01-31AL-VCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-458-0355 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APL11-1-53F-403 | Sensata Technologies Maryland, Inc |
APL11-1-53F-403 | Myers Power Products, Inc. |
Stock Check
![](/public/images/partscage_shelf3.png)