Overload Switch
Current rating amperes 50.0 voltage frequency and tripping time delay code letter l, resistance or impedance ohms max .003.
Manufacturer part number M55629/1-422 for national stock number 5925014695727.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-469-5727.
-
MPN or Model
M55629/1-422
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
2.530 inches -
Body Width
0.755 inches -
Body Height
2.553 inches -
Center To Center Distance Between Terminals Parallel To Length
1.810 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
End Application
5896-01-433-6254 -
Boss Height
0.140 inches -
Pole Quantity
1 -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual
More from these suppliers
- 5905-00-001-8625 MPN MIL-R-39005/2Noninductive Wire Wound Fixed Resistor
- 5905-00-004-5797 MPN RNC65H9532FRFilm Fixed Resistor
- 5905-00-004-6033 MPN RBR71L24181BMNoninductive Wire Wound Fixed Resistor
- 5905-00-005-2665 MPN MILR39005-6Noninductive Wire Wound Fixed Resistor
- 5905-00-006-5498 MPN RNC60H8451BPFilm Fixed Resistor
- 5905-00-006-5576 MPN RNC60K1302FRFilm Fixed Resistor
- 5935-00-009-2994 MPN MILC26500Electrical Plug Connector
- 5935-00-009-6394 MPN M83723/76R16247Electrical Plug Connector
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-469-5727 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M55629/1-422 | Military Specifications |
MIL-C55629/1 | Military Specifications |
MIL-C55629/1 | Military Specifications |
MIL-C55629/1 | Military Specifications |
M55629/1-422 | Military Specifications |
MIL-C55629/1 | Military Specifications |
M55629/1-422 | Military Specifications |
MIL-C55629/1 | Military Specifications |
M55629/1-422 | Military Specifications |
MIL-C55629/1 | Military Specifications |
M55629/1-422 | Military Specifications |
MIL-C55629/1 | Military Specifications |