Overload Switch

About this product

2 poles, 150.0 amperes dc all locations maximum continuous load current rating per pole, 28.0 dc all locations operating voltage type and rating per pole in volts, maximum interrupting capacity current type and rating per pole in amps: 14000.0 dc all locations.

Manufacturer part number GJ2-Z35-2 for national stock number 5925014711761.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-01-471-1761.

  • MPN or Model

    GJ2-Z35-2

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    4.4 lb
  • Body Length
    7.125 inches
  • Body Width
    3.000 inches
  • Body Height
    2.969 inches
  • Center To Center Distance Between Terminals Parallel To Width
    1.500 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    3.828 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
    1.500 inches
  • End Application
    5805-01-452-5730, central office telephone automatic
  • Boss Height
    0.219 inches
  • Pole Quantity
    2
  • Maximum Continuous Load Current Rating Per Pole
    150.0 amperes dc all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    28.0 dc all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    14000.0 dc all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Magnetic-hydraulic all locations
  • Trip Release Characteristic
    Time delay all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    125.0 all locations
  • Reset Method
    Manual
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-01-471-1761 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925014711761

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
GJ2-Z35-2 Eaton Corp
29-2733550-2 General Dynamics Mission Systems,
GJ2-Z35-2 Eaton Corp
29-2733550 General Dynamics Mission Systems,
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.