NSN 5925-01-472-6511
Overload Switch
1 poles, 250.0 amperes ac single location and 65.0 amperes dc single location maximum continuous load current rating per pole, 250.0 ac single location and 65.0 dc single location operating voltage type and rating per pole in volts, maximum interrupting capacity current type and rating per pole in amps: 10.0 ac single location.
Manufacturer part number 804785-2 for national stock number 5925014726511.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-472-6511.
-
MPN or Model
804785-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
End Application
Tornado nose radar -
Pole Quantity
1 -
Maximum Continuous Load Current Rating Per Pole
250.0 amperes ac single location and 65.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 65.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10.0 ac single location -
Circuit Protection Type
Overvoltage single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
200.0 single location -
Internal Trip Release Configuration
Series trip single location -
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 at 200 pct single location -
Frequency In Hertz
60.0 single location
More from these suppliers
- 5950-00-092-6306 MPN 752395-1Power Transformer
- 5905-00-111-4743 MPN 418766-61Composition Fixed Resistor
- 5905-00-141-1165 MPN 418766-107Composition Fixed Resistor
- 5905-00-171-2004 MPN 411336-119Composition Fixed Resistor
- 5950-00-178-8549 MPN 20101Power Autotransformer Transformer
- 5975-00-214-9117 MPN 404985-1Conduit Outlet Cover
- 5905-00-243-7960 MPN RN55D3922FFilm Fixed Resistor
- 5905-00-284-3894 MPN 531511-203Film Fixed Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-472-6511 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
804785-2 | Raytheon Company |
Stock Check
![](/public/images/partscage_shelf3.png)