NSN 5925-01-478-3537
Overload Switch
Multipole-single actuator type body style, 2 poles, 50.0 amperes dc single location maximum continuous load current rating per pole, trip release method: magnetic single location.
Manufacturer part number UPG-66-1-51-103-01 for national stock number 5925014783537.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-478-3537.
-
MPN or Model
UPG-66-1-51-103-01
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
2.000 inches -
Body Width
2.000 inches -
Body Height
2.030 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.005 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.660 inches -
End Application
Boat, personnel 13 meter 13mpe 9904 -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 terminal -
Maximum Continuous Load Current Rating Per Pole
50.0 amperes dc single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
100.0 single location -
Reset Method
Manual -
Terminal Type And Quantity
2 screw
More from these suppliers
- 5925-00-236-2350 MPN UPGH111-1REC4-2630-4Circuit Breaker
- 5925-01-018-6844 MPN APL-1-1-52-502Circuit Breaker
- 5925-01-086-5998 MPN AP12-1R6-1-500Circuit Breaker
- 5925-01-250-3812 MPN 205-111-1-65-5A-502Circuit Breaker
- 5925-01-272-8157 MPN AP-112-6462-1Circuit Breaker
- 5925-01-357-9146 MPN 229-3-1-64-5-9-50Circuit Breaker
- 5925-01-359-5916 MPN AP112-42-0501RCircuit Breaker
- 5925-01-400-0818 MPN AP-17-1-79-302Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-478-3537 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UPG-66-1-51-103-01 | Sensata Technologies Maryland, Inc |