NSN 5925-01-486-5631
Overload Switch
3 poles, 75.0 amperes dc second location maximum continuous load current rating per pole, 65.0 dc all locations operating voltage type and rating per pole in volts, maximum interrupting capacity current type and rating per pole in amps: 52.0 dc all locations.
Manufacturer part number IULNK111-28450-3 for national stock number 5925014865631.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-486-5631.
-
MPN or Model
IULNK111-28450-3
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Bushing Length
15.9 millimeters -
Body Length
63.3 millimeters -
Body Width
57.5 millimeters -
Center To Center Distance Between Terminals Parallel To Length
49.3 millimeters -
Center To Center Distance Between Terminals Parallel To Width
19.1 millimeters -
Mounting Surface To Terminal End Distance
72.5 millimeters -
Pole Quantity
3 -
Maximum Continuous Load Current Rating Per Pole
75.0 amperes dc second location -
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
52.0 dc all locations -
Trip Release Characteristic
Time delay all locations -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Reset -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5905-00-051-7594 MPN X900337Precision Wire Wound Variable Resistor
- 5305-00-826-3217 MPN 1-64X1-4SSTMachine Screw
- 5925-00-064-1153 MPN 501I302Circuit Breaker
- 5925-00-192-0767 MPN AP12-206-1Circuit Breaker
- 5925-01-040-7247 MPN AP-MIL-1-7-2-102Circuit Breaker
- 5925-01-145-9191 MPN APL1-1RE-4297-1Circuit Breaker
- 5925-01-320-2498 MPN APG-6-1REC2-62-102-01Circuit Breaker
- 5925-01-322-7930 MPN R25-2-2.00A-B121EVCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-486-5631 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
IULNK111-28450-3 | Sensata Technologies Maryland, Inc |
914203-3 | General Dynamics Land Systems |
Stock Check
![](/public/images/partscage_shelf3.png)