NSN 5925-01-488-6619
Overload Switch
F in p/n denotes addition of initial delay.
Manufacturer part number AP-117-1-42F-203 for national stock number 5925014886619.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-488-6619.
-
MPN or Model
AP-117-1-42F-203
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Bushing Length
0.380 inches -
Body Length
1.562 inches -
Body Width
1.937 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.875 inches -
Center To Center Distance Between Terminals Parallel To Width
0.625 inches -
Nonturn Device Location
At 3 oclock and at 9 oclock -
Nonturn Device Length
Between 0.005 inches and 0.015 inches -
Nonturn Device Diameter
0.250 inches -
Fragility Factor
Moderately rugged -
End Application
Guardrail -
Mounting Surface To Terminal End Distance
1.950 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Cubic Measure
8.941 cubic inches -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 at 200 pct all locations and 9.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant and hermetically sealed -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unef -
Terminal Type And Quantity
6 tab w/screw -
Specification Data
29957-5114-1803 manufacturers specification control
More from these suppliers
- 5925-00-488-2741 MPN APL-1-1R0-42-501-MCircuit Breaker
- 5925-01-063-1766 MPN 203-22-1-63F203-4-1-1ACircuit Breaker
- 5925-01-249-4752 MPN 219-3-1-63F-7-8-20Circuit Breaker
- 5925-01-265-0829 MPN 203-11-2-51F-102-1-1Circuit Breaker
- 5925-01-301-9777 MPN APGN-444-22237-1Circuit Breaker
- 5925-01-322-7925 MPN 209-1-1-51-2-8-50-HCircuit Breaker
- 5925-01-359-6329 MPN AP-1-1R-50-752Circuit Breaker
- 5925-01-369-7525 MPN AP112-23206-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-488-6619 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AP-117-1-42F-203 | Sensata Technologies Maryland, Inc |