NSN 5925-01-489-2791
Overload Switch
Fully sealed magnetic circuit breaker; single pole unit, mounted with 0.375 in. Threaded bushing; series with auxiliary switch with cane hook terminals; dc, 50/60hz, 400hz long time delay 135 percent trip with additional inertial delay; 10 amp nominal rating.
Manufacturer part number AP-1-1RC-72F-103 for national stock number 5925014892791.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-489-2791.
-
MPN or Model
AP-1-1RC-72F-103
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Single pole type -
Bushing Length
0.380 inches -
Body Length
1.562 inches -
Body Width
1.281 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.875 inches -
Switch Contact Arrangement
Single pole, double throw -
Mounting Surface To Terminal End Distance
1.780 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.375 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 at 200 pct single location and 1.700 at 200 pct single location -
Inclosure Protection Type For Which Designed
Hermetically sealed -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
0.5 dc -
Switch Voltage Rating And Type In Volts
50.0 dc -
Frequency In Hertz
50.0 single location or 60.0 single location -
Unpackaged Unit Weight
1.800 ounces -
Thread Series Designator
Unef -
Terminal Type And Quantity
2 wire hook
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-489-2791 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AP-1-1RC-72F-103 | Vdo Control Systems Inc |