NSN 5925-01-497-1097
Overload Switch
Single pole type body style, metal case material, single pole, single throw, normally closed switch contact arrangement, pole quantity: 1.
Manufacturer part number M39019/02-263S for national stock number 5925014971097.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-497-1097.
-
MPN or Model
M39019/02-263S
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Bushing Length
Between 0.332 inches and 0.380 inches -
Body Length
1.562 inches -
Body Width
0.625 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.906 inches -
Switch Contact Arrangement
Single pole, single throw, normally closed -
End Application
Weapon launch consol assembly for los angeles class submarine 688 -
Mounting Surface To Terminal End Distance
1.810 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
1.5 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location and 50.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location and 500.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
800.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.375 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 at 200 pct single location and 0.950 at 200 pct single location and 0.240 at 400 pct single location and 0.060 at 800 pct single location -
Inclosure Protection Type For Which Designed
Corrosion resistant and fungus resistant and hermetically sealed -
Trip Release Ambient Tempurature Rating
23.0 degrees celsius single location and 27.0 degrees celsius single location -
Frequency In Hertz
60.0 single location or 400.0 single location -
Test Data Document
81349-mil-c-39019 specification specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unef -
Terminal Type And Quantity
2 screw -
Specification Data
81349-mil-c-39019/2 government specification
More from these suppliers
- 4820-00-045-5445 MPN 13G0045-262Valve Stem
- 5935-00-110-3146 MPN 5175113-003Tip Jack
- 4820-00-142-2770 MPN YW111S4825-263106PC28Valve Disk
- 4820-00-180-7686 MPN 820-2179102-32Check Valve Cap
- 5975-00-284-9340 MPN 329108-145Stuffing Tube Packing Nut
- 4820-00-287-3327 MPN 55400-5900-871189PC6267Globe Valve
- 4820-00-288-7842 MPN 352-2200-484792PCV9188Safety Relief Valve
- 4820-00-336-5986 MPN AM57S55-111ALT1PC45Fluid Valve Stem
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-497-1097 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M39019/02-263S | Military Specifications |
MIL-PRF-39014/2 | Military Specifications |
462-7068566-95 | Naval Sea Systems Command |
H851-2001-95 | Electric Boat Corporation |
7068566 | Naval Sea Systems Command |