NSN 5925-01-506-0529
Overload Switch
Multipole-multiple actuator type body style, 3 poles, 10.0 amperes ac all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 265.0 ac all locations.
Manufacturer part number AM3R-Z103-1 for national stock number 5925015060529.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-506-0529.
-
MPN or Model
AM3R-Z103-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
2.500 inches -
Body Width
2.250 inches -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
End Application
Test station electrical-electronic equipment -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
2.860 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
6 clip -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
265.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Frequency In Hertz
47.0 all locations or 440.0 all locations
More from these suppliers
- 5935-00-060-7947 MPN 555164-501Electrical Plug Connector
- 5985-00-137-3596 MPN A75958-001Radio Frequency Transmission Line
- 5950-00-203-1256 MPN 666231-908Radio Frequency Transformer
- 5935-00-340-2809 MPN 43167-000Electrical Plug Connector
- 5950-00-646-3922 MPN SC647275Pulse Transformer
- 5945-00-665-8612 MPN 647162Electromagnetic Relay
- 5950-00-730-8100 MPN 810000-861Reactor
- 5935-00-925-6305 MPN 555454-522Electrical Receptacle Connector Body
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-506-0529 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM3R-Z103-1 | Eaton Corp |
6012329-002 | Bae Systems Information And |
6012329 | Bae Systems Information And |
AM3R-Z103-1W | Heinemann Electric Canada |