NSN 5925-01-511-2811
Overload Switch
3 poles, 240.0 ac all locations operating voltage type and rating per pole in volts, 1000.0 ac all locations maximum interrupting capacity current type and rating per pole in amps, circuit protection type: overcurrent all locations.
Manufacturer part number M55629/5-REWEWE for national stock number 5925015112811.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-511-2811.
-
MPN or Model
M55629/5-REWEWE
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Length
2.330 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
End Application
Sb-4413/spn-3; w/s - an/spn-42t-3, 42t-4; an/spn-46 (v) 1 -
Boss Height
0.140 inches -
Pole Quantity
3 -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Manual Actuator Type And Quantity
3 toggle -
Trip Delay Time In Seconds Per Rated Continuous Current
5.000 at 150 pct all locations and 60.000 at 150 pct all locations -
Inclosure Protection Type For Which Designed
Hermetically sealed -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius all locations -
Switch Current Rating And Type In Amps
10.0 ac and 30.0 ac and 30.0 ac -
Switch Voltage Rating And Type In Volts
240.0 ac -
Frequency In Hertz
400.0 all locations -
Test Data Document
81349-mil-prf-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Terminal Type And Quantity
6 threaded stud -
Specification Data
81349-mil-prf-55629/5 government specification
More from these suppliers
- 5905-00-003-5714 MPN RR1000D2C8G502Nonprecision Wire Wound Variable Resistor
- 5905-00-004-6054 MPN RER60F33R0RInductive Wire Wound Fixed Resistor
- 5905-00-004-7651 MPN MIL-R-55182/7Film Fixed Resistor
- 5935-00-005-2834 MPN MILC83723-74Electrical Receptacle Connector
- 5905-00-006-1289 MPN MIL-R-55182/3Film Fixed Resistor
- 5905-00-006-5487 MPN MILR39017-4Film Fixed Resistor
- 5905-00-006-9065 MPN RLR05C513GPFilm Fixed Resistor
- 5935-00-007-9213 MPN M21097/14-13Electrical Receptacle Connector
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-511-2811 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M55629/5-REWEWE | Military Specifications |
MIL-PRF-55629/5 | Military Specifications |