NSN 5925-01-512-8126
Overload Switch
Multipole-single actuator type body style, metal case material, 2 poles, maximum continuous load current rating per pole: 10.0 amperes dc all locations.
Manufacturer part number 11622 for national stock number 5925015128126.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-512-8126.
-
MPN or Model
11622
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Bushing Length
0.380 inches -
Body Length
1.562 inches -
Body Width
1.281 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.875 inches -
Center To Center Distance Between Terminals Parallel To Width
0.625 inches -
End Application
Navy equipment -
Mounting Surface To Terminal End Distance
1.780 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations -
Reset Method
Manual -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Part Name Assigned By Controlling Agency
Magnetic circuit breaker -
Thread Series Designator
Unef -
Terminal Type And Quantity
4 tab w/screw
More from these suppliers
- 6110-01-471-3771 MPN 12220Power Line Conditioner
- 5925-00-417-2644 MPN AOL-1-1R0-51-303Circuit Breaker
- 5925-00-726-0122 MPN APL111F4-153FCircuit Breaker
- 5925-01-075-7136 MPN AP12-4613-12Circuit Breaker
- 5925-01-096-8606 MPN AP112-12KCircuit Breaker
- 5925-01-114-0906 MPN AP1167064-243Circuit Breaker
- 5925-01-114-8254 MPN APGX6-3374-2Circuit Breaker
- 5925-01-141-6684 MPN AP-12-1R-62F-751Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-512-8126 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
11622 | Ap Labs, Inc. |
AP17-1-71-103 | Sensata Technologies Maryland, Inc |
AP17-1-71-103 | Sensata Technologies Maryland, Inc |