NSN 5925-01-512-9057
Overload Switch
3 poles, 250.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts, circuit protection type: undervoltage all locations.
Manufacturer part number JGL3600S25UA for national stock number 5925015129057.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-512-9057.
-
MPN or Model
JGL3600S25UA
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
End Application
Circuit breaker panel -
Pole Quantity
3 -
Maximum Continuous Load Current Rating Per Pole
250.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations -
Circuit Protection Type
Undervoltage all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Internal Trip Release Configuration
Shunt trip all locations
More from these suppliers
- 5930-01-435-1895 MPN ZA2-BW14Push Switch
- 5945-01-450-8687 MPN 9065SR220Solid State Relay
- 5930-01-561-7286 MPN ZB4BS54Push Button
- 5930-01-463-9306 MPN 9421 VC4GEElectronic Switch
- 5930-01-246-5443 MPN 92251Box Switch
- 5930-01-580-0532 MPN XB4BS8445Push Button
- 6110-01-432-3699 MPN LC1D25M7Magnetic Contactor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-512-9057 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
JGL3600S25UA | Schneider Electric Usa, Inc. |
AV6000E13 NOM.03 | Federal Equipment Company |
AV6000E13 | Federal Equipment Company |
KHL36000M1121 | Schneider Electric Usa, Inc. |
JGL3600S25UA | Schneider Electric Usa, Inc. |
AV6000E13 NOM.03 | Federal Equipment Company |
KHL36000M1121 | Schneider Electric Usa, Inc. |
AV6000E13 | Federal Equipment Company |
JGL3600S25UA | Schneider Electric Usa, Inc. |
AV6000E13 NOM.03 | Federal Equipment Company |
KHL36000M1121 | Schneider Electric Usa, Inc. |
AV6000E13 | Federal Equipment Company |
JGL3600S25UA | Schneider Electric Usa, Inc. |
AV6000E13 NOM.03 | Federal Equipment Company |
KHL36000M1121 | Schneider Electric Usa, Inc. |
AV6000E13 | Federal Equipment Company |
JGL3600S25UA | Schneider Electric Usa, Inc. |
AV6000E13 NOM.03 | Federal Equipment Company |
KHL36000M1121 | Schneider Electric Usa, Inc. |
AV6000E13 | Federal Equipment Company |