1-321-802-5889

NSN 5925-01-513-4452

Overload Switch

About this product

Adj thermal and fix magnetic trip; w/o terminals.

Manufacturer part number FWC3160JVWA0601 for national stock number 5925015134452.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-01-513-4452.

  • MPN or Model

    FWC3160JVWA0601

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Body Length
    152.400 inches
  • Body Width
    70.670 inches
  • Body Height
    85.730 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    119.080 inches
  • Center To Center Distance Between Terminals Parallel To Width
    34.930 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    114.300 inches
  • Switch Contact Arrangement
    Single pole, double throw
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
    34.930 inches
  • End Application
    Load ctr 28b ddg91
  • Boss Height
    4.170 inches
  • Pole Quantity
    3
  • Mounting Facility Type And Quantity
    4 threaded hole
  • Maximum Continuous Load Current Rating Per Pole
    160.0 amperes ac all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    690.0 ac all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    18000.0 ac all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Thermal-magnetic all locations
  • Trip Release Characteristic
    Instantaneous all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    200.0 all locations
  • Ultimate Trip Time Per Pole In Seconds
    4.000 all locations and 20.000 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole two
  • External Actuator Linkage Arrangement
    One, two, and three linked
  • Auxiliary Switch Function And Quantity
    1 control
  • Thread Size
    0.164 inches
  • Switch Location And Position Designation
    Internal at pole one
  • Trip Release Ambient Tempurature Rating
    50.0 degrees celsius all locations
  • Switch Terminal Type
    Wire lead
  • Switch Current Rating And Type In Amps
    6.0 ac
  • Frequency In Hertz
    50.0 all locations or 60.0 all locations
  • Thread Series Designator
    Unc
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-01-513-4452 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925015134452

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
FWC3160JVWA0601 L-3 Communications Westwood
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.