NSN 5925-01-517-7229
Overload Switch
Operates in m40.0-85.0 deg c; insulation resistance not less than 100 megohms at 500 volts dc; dielectric strength withstands 3750 vac, 60 hz for 60 seconds between all electricity isolated terminals, except auxiliary switch terminsal shall withstand 600 vac, 60 hz for reg and rec types; operating as a switch the operating life exceeds 10,000 operations at a rate of 6 per minute when tested as follows 6000 ops at rated current plus 4000 ops at no load; electrical characteristics 0.050-50 amperes; 80vdc max, 240vac max, 50/60 hz and 0.050-30 amperes; 250vac max, 400 hz; one toggle handle per unit; handle color red.
Manufacturer part number IEG6-IREC4-61-15.0-21-V for national stock number 5925015177229.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-517-7229.
-
MPN or Model
IEG6-IREC4-61-15.0-21-V
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Single pole type -
Body Length
2.000 inches -
Body Width
0.750 inches -
Body Height
2.075 inches -
Boss Height
0.240 inches -
Pole Quantity
1 -
Frequency In Hertz
50.0 single location or 60.0 single location -
Supplementary Features
Pct overload-trip time in seconds 100 pct no trip, 125 pct 0.7-12, 150 pct 0.35-7, 200 pct 0.130-3, 400 pct 0.030-1, 600 pct 0.015-0.3, 800 pct 0.01-0.15, 1000 pct 0.008-0.1 -
Test Data Document
Mil-std-202 standard (includes industry or association standards, individual manufactureer standards, etc.).
More from these suppliers
- 5925-01-037-6891 MPN AP1-1R4-2-501Circuit Breaker
- 5925-01-069-2995 MPN APL112-3510-1Circuit Breaker
- 5925-01-277-4005 MPN AP-12-1-71F-102Circuit Breaker
- 5925-01-392-6280 MPN APG-1-1-50-252Circuit Breaker
- 5925-01-441-9316 MPN AP17-1-64F-752Circuit Breaker
- 5925-01-449-1244 MPN 203-2-1-62-502-4-1-1Circuit Breaker
- 5925-01-501-5145 MPN IELK1-30372-15Circuit Breaker
- 5925-01-501-5163 MPN IELK1-30372-4Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-517-7229 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
IEG6-IREC4-61-15.0-21-V | Sensata Technologies Maryland, Inc |
AM-344 | Sensata Technologies Maryland, Inc |