NSN 5925-01-520-8091
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number UPL111-1-66-303 for national stock number 5925015208091.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-520-8091.
-
MPN or Model
UPL111-1-66-303
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
Between 2.468 inches and 2.532 inches -
Body Width
2.265 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.906 inches and 1.970 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.718 inches and 0.782 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.030 inches and 2.094 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.718 inches and 0.782 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.108 inches and 0.172 inches -
Mounting Surface To Terminal End Distance
Between 2.688 inches and 2.752 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 at 200 pct all locations and 85.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Dustproof and fungus proof -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5930-01-607-4082 MPN IULHK111-1-66-20.0-E-90Toggle Switch
- 5925-00-168-3645 MPN AP12-573-4Circuit Breaker
- 5925-00-272-8898 MPN APL111-1-62-303-MCircuit Breaker
- 5925-01-087-9238 MPN UPL1-138-13Circuit Breaker
- 5925-01-157-9949 MPN APG-7-7332-1Circuit Breaker
- 5925-01-161-8091 MPN APL111-1R0-7044-1Circuit Breaker
- 5925-01-225-0534 MPN 203-1-9221-1Circuit Breaker
- 5925-01-298-1191 MPN UPG-11-1-61-501-01Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-520-8091 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UPL111-1-66-303 | Sensata Technologies Maryland, Inc |