1-321-802-5889

NSN 5925-01-552-4945

Overload Switch

About this product

2 electrically isolated coils; coil number 1 time delay; coil number 2 instantaneously tripped by current(220.0 volts, 50.0 to 60.0 hertz, 30.0 va), supplied by control equipment or remote monitoring system; ultimate trip rating for coil 2 is 120.0 percent.

Manufacturer part number GH3Z3031 for national stock number 5925015524945.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-01-552-4945.

  • MPN or Model

    GH3Z3031

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • Body Style
    Multipole-single actuator type
  • Mounting Slot Width
    0.203 inches
  • Body Length
    6.000 inches
  • Body Width
    4.125 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    5.000 inches
  • Center To Center Distance Between Terminals Parallel To Width
    1.375 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    4.687 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
    1.375 inches
  • Boss Height
    0.250 inches
  • Mounting Surface To Terminal End Distance
    3.125 inches
  • Pole Quantity
    3
  • Mounting Facility Type And Quantity
    4 slot
  • Maximum Continuous Load Current Rating Per Pole
    3.0 amperes ac all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    480.0 ac all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    5000.0 ac all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Magnetic-hydraulic all locations
  • Auxiliary Trip Coil Voltage Type And Rating In Volts
    220.0 ac all locations
  • Trip Release Characteristic
    Instantaneous all locations and time delay all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    125.0 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Internal Trip Release Configuration
    Series/relay trip all locations
  • Trip Release Duty Cycle
    Intermittent all locations
  • Trip Delay Time In Seconds Per Rated Continuous Current
    0.150 at 200 pct all locations and 0.600 at 200 pct all locations
  • Frequency In Hertz
    50.0 all locations or 60.0 all locations
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-01-552-4945 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925015524945

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
GH3Z3031 Eaton Corp
GH3Z3031 Heinemann Electric Canada
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.