NSN 5925-01-552-7439
Overload Switch
Shunt trip operates at 75 percent or more of rated voltage; trips from remote location.
Manufacturer part number FAL240201027 for national stock number 5925015527439.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-552-7439.
-
MPN or Model
FAL240201027
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
6.000 inches -
Body Width
3.000 inches -
Body Height
3.160 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
5.130 inches -
Unthreaded Mounting Hole Diameter
0.440 inches -
End Application
Aps cont cubicle pazz pa20397/2150 -
Boss Height
3.160 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
2 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Reset Method
Manual -
Manual Actuator Type And Quantity
1 toggle -
Part Name Assigned By Controlling Agency
Thermal-magnetic molded case circuit breakers -
Terminal Type And Quantity
4 tab w/screw
More from these suppliers
- 5930-00-102-5908 MPN 9001G03SYM16Push Switch
- 5930-01-267-1068 MPN DU324Box Switch
- 5945-01-374-0754 MPN 9050-JCK-16-120VSolid State Relay
- 5930-01-323-6651 MPN 9007-C66-B2Sensitive Switch
- 5925-00-199-9548 MPN FAL34100Circuit Breaker
- 5925-00-374-1690 MPN B11.5Circuit Breaker Thermal Release
- 5925-01-665-9266 MPN M9F15306Circuit Breaker
- 6110-01-306-4389 MPN LP1-259BA65Magnetic Contactor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-552-7439 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
FAL240201027 | Schneider Electric Usa, Inc. |
PA20397/2150 ITEM 61 | Alstom Power Conversion Inc. |