NSN 5925-01-566-7194
Overload Switch
Dc motor start.
Manufacturer part number IUGN6-1-53-2.50 for national stock number 5925015667194.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-566-7194.
-
MPN or Model
IUGN6-1-53-2.50
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
2.000 inches -
Body Width
0.750 inches -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
End Application
Barrier boat 25bb0501 25-11.3 z -
Mounting Surface To Terminal End Distance
2.256 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Maximum Continuous Load Current Rating Per Pole
2.5 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
80.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip w/separate reset -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.500 inches and 0.138 inches -
Part Name Assigned By Controlling Agency
Magnetic circuit breaker/protector -
Unpackaged Unit Weight
2.200 ounces -
Thread Series Designator
Unc and un -
Terminal Type And Quantity
2 screw
More from these suppliers
- 5925-00-595-8846 MPN APL11-55629-3-080Circuit Breaker
- 5925-00-708-1605 MPN 520B302Circuit Breaker
- 5925-01-096-4699 MPN AP112-1-4-2-402Circuit Breaker
- 5925-01-290-4754 MPN UPL111-22854-004Circuit Breaker
- 5925-01-338-0968 MPN 219-3-1R66-5-8-30ACircuit Breaker
- 5925-01-351-0641 MPN UPG-6-1-66-303-01Circuit Breaker
- 5925-01-367-2519 MPN AP-12-7895-1Circuit Breaker
- 5925-01-530-3159 MPN IELK1-33195-12Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-566-7194 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
IUGN6-1-53-2.50 | Sensata Technologies Maryland, Inc |