NSN 5925-01-591-6139
Overload Switch
Suitable for applications where high levels of inrush current are expected; prevents nuisance tripping in high inductive apps.
Manufacturer part number FAZ-D10/3-NA for national stock number 5925015916139.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-591-6139.
-
MPN or Model
FAZ-D10/3-NA
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Multipole-multiple actuator type -
Body Length
105.0 millimeters -
Body Width
53.1 millimeters -
Body Height
44.0 millimeters -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Width
17.7 millimeters -
End Application
Aircraft c295 -
Boss Height
16.0 millimeters -
Pole Quantity
3 -
Mounting Facility Type And Quantity
Din rail -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations and 10.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac all locations and 480.0 ac all locations and 96.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations and 10000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
1000.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one and at pole two and at pole three -
External Actuator Linkage Arrangement
One, two, and three linked -
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 800 pct pascal all locations and 90.000 18 stage pascal all locations -
Part Name Assigned By Controlling Agency
Faz na branch circuit breaker type d for highly inductive load -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Terminal Type And Quantity
6 screw
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-591-6139 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
FAZ-D10/3-NA | Moeller Instrument Company, Inc. |