NSN 5925-01-592-9196
Overload Switch
Multipole-single actuator type body style, plastic case material, 3 poles, maximum continuous load current rating per pole: 60.0 amperes ac all locations.
Manufacturer part number CD3-C3-DU-60-240-1 for national stock number 5925015929196.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-592-9196.
-
MPN or Model
CD3-C3-DU-60-240-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
5.125 inches -
Body Width
3.138 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.547 inches -
Center To Center Distance Between Terminals Parallel To Width
1.026 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.026 inches -
Boss Height
0.219 inches -
Mounting Surface To Terminal End Distance
3.485 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
4 threaded hole -
Maximum Continuous Load Current Rating Per Pole
60.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
1000.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Nontrip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one and at pole two and at pole three -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
35.000 at 200 pct all locations and 150.000 at 200 pct all locations -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 screw
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-592-9196 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
CD3-C3-DU-60-240-1 | Eaton Corp |
CD3-C3-DU-60-240-1 | Heinemann Electric Canada |