NSN 5925-01-595-2375
Overload Switch
Single pole type body style, 0.130 inches mounting slot width, metal case material, pole quantity: 1.
Manufacturer part number AP7-1-50-153 for national stock number 5925015952375.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-595-2375.
-
MPN or Model
AP7-1-50-153
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Single pole type -
Mounting Slot Width
0.130 inches -
Bushing Length
0.380 inches -
Body Length
1.562 inches -
Body Width
1.281 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.875 inches -
Mounting Surface To Terminal End Distance
1.605 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 slot -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
15.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
100.0 single location -
Reset Method
Automatic -
Trip Delay Time In Seconds Per Rated Continuous Current
40.0 at 100 pct and 0.015 at 800 pct single location -
Terminal Type And Quantity
2 quick disconnect, male
More from these suppliers
- 5930-01-435-4266 MPN UPL-000-26644-1Toggle Switch
- 5925-00-058-6363 MPN APL1-532-420Circuit Breaker
- 5925-00-107-4230 MPN APL1-1176-12Circuit Breaker
- 5925-00-307-4015 MPN APL1-55629-1-066Circuit Breaker
- 5925-00-935-5273 MPN AP1-1-5-2-103Circuit Breaker
- 5925-01-038-1349 MPN 520A501Circuit Breaker
- 5925-01-119-4386 MPN 203-2-1-43-502-4-1-1Circuit Breaker
- 5925-01-120-9108 MPN 299-3-3283-10Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-595-2375 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AP7-1-50-153 | Sensata Technologies Maryland, Inc |