NSN 5925-01-598-3939
Overload Switch
Cms data id 2958, pccn, plisn a003.
Manufacturer part number AA2-B0-46-630-121-C for national stock number 5925015983939.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-598-3939.
-
MPN or Model
AA2-B0-46-630-121-C
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Multipole-multiple actuator type -
Body Length
2.0 inches -
Body Width
1.515 inches -
Center To Center Distance Between Terminals Parallel To Length
1.56 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.66 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.75 inches -
End Application
0000-1-lg9-7307; mpd 85-015 (60955); p/n mpd 85-015 -
Mounting Surface To Terminal End Distance
2.0 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 threaded hole -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Instantaneous single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip single location -
Trip Release Duty Cycle
Continuous single location -
Part Name Assigned By Controlling Agency
Breaker, circuit -
Terminal Type And Quantity
4 quick disconnect, male
More from these suppliers
- 5930-01-237-7329 MPN 112-PAMPush Switch
- 5930-01-578-9056 MPN L70B1XDDA-3AAEK-1XX-XTC1Toggle Switch
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-598-3939 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AA2-B0-46-630-121-C | Carling Technologies, Inc |