NSN 5925-01-602-6804
Overload Switch
Multipole-single actuator type body style, plastic case material, 3 poles, maximum continuous load current rating per pole: 15.0 amperes dc all locations.
Manufacturer part number HFDDC4015L for national stock number 5925016026804.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-602-6804.
-
MPN or Model
HFDDC4015L
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
6.0 inches -
Body Width
5.5 inches -
Body Height
3.38 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Width
1.38 inches -
Unthreaded Mounting Hole Diameter
0.45 inches -
End Application
Controller as -
Boss Height
0.12 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
8 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 dc all locations -
Circuit Protection Type
Reverse current all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
225.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Nontrip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius all locations -
Terminal Type And Quantity
8 screw
More from these suppliers
- 5930-00-201-3423 MPN S1258841Push Switch
- 5945-00-515-2192 MPN 372D621G14Thermal Relay
- 5930-01-038-9680 MPN 0T2B1-0T2APush Switch
- 5930-01-424-5844 MPN 6642C15G08Sensitive Switch
- 5945-01-478-8515 MPN 6593C20H02Relay Contact Set
- 5930-01-481-6713 MPN 504C323G08Switch Handle
- 5950-01-167-8862 MPN 505C806G40Electrical Coil
- 5925-00-762-2430 MPN 656D964G06Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-602-6804 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
HFDDC4015L | Eaton Corporation |
3184E003-45 | C.s. Controls, Incorporated |
PL3184E003 ITEM 45 | C.s. Controls, Incorporated |