1-321-802-5889

NSN 5925-01-604-3995

Overload Switch

About this product

Single pole type body style, 1 poles, 32 thready qty per inch (tpi), maximum continuous load current rating per pole: 20.0 amperes dc single location.

Manufacturer part number IUGN6-1-52-20.0 for national stock number 5925016043995.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-01-604-3995.

  • MPN or Model

    IUGN6-1-52-20.0

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Body Style
    Single pole type
  • Body Length
    2.0 inches
  • Body Width
    0.75 inches
  • Center To Center Distance Between Terminals Parallel To Length
    1.53 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    1.66 inches
  • End Application
    Boat, rigid i
  • Mounting Surface To Terminal End Distance
    2.075 inches
  • Pole Quantity
    1
  • Mounting Facility Type And Quantity
    2 threaded hole
  • Thready Qty Per Inch (tpi)
    32
  • Maximum Continuous Load Current Rating Per Pole
    20.0 amperes dc single location
  • Operating Voltage Type And Rating Per Pole In Volts
    250.0 dc single location
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    7500.0 dc single location
  • Circuit Protection Type
    Reverse current single location
  • Trip Release Method
    Magnetic single location
  • Trip Release Characteristic
    Time delay single location
  • Reset Method
    Manual
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Internal Trip Release Configuration
    Series trip single location
  • Thread Size
    0.138 inches
  • Trip Delay Time In Seconds Per Rated Continuous Current
    1.2 at 100 pct single location
  • Thread Series Designator
    Unc
  • Terminal Type And Quantity
    2 screw
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-01-604-3995 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925016043995

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
IUGN6-1-52-20.0 Sensata Technologies Maryland, Inc
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.