NSN 5925-01-607-2091
Overload Switch
Multipole-single actuator type body style, metal case material, single pole, double throw switch contact arrangement, pole quantity: 2.
Manufacturer part number AP17-1R-62-252 for national stock number 5925016072091.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-607-2091.
-
MPN or Model
AP17-1R-62-252
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Bushing Length
0.625 inches -
Body Length
1.562 inches -
Body Width
1.281 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.875 inches -
Center To Center Distance Between Terminals Parallel To Width
0.625 inches -
Switch Contact Arrangement
Single pole, double throw -
End Application
K10048561-50 (29355) , assembly tray -
Mounting Surface To Terminal End Distance
1.78 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
2 threaded hole and 1 threaded bushing w/panel seal -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
2500.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc and 120.0 ac and 240.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
400.0 all locations -
Ultimate Trip Time Per Pole In Seconds
135.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
Between pole one and two -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.8 at 200 pct and 8.0 at 200 pct all locations -
Switch Terminal Type
Tab, solder lug -
Part Name Assigned By Controlling Agency
Hydraulic magnetic circuit protector, fully sealed, two pole unit, bushing plus (2) 6-32 threaded inserts, series, 50/60hz long delay, 2500 amps -
Frequency In Hertz
50.0 or 60.0 all locations -
Thread Series Designator
Un -
Terminal Type And Quantity
4 screw
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-607-2091 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AP17-1R-62-252 | Airpax Electronics Inc |