NSN 5925-01-620-5008
Overload Switch
Single pole type body style, plastic case material, 1 poles, thready qty per inch (tpi): 32.
Manufacturer part number AM1RA3AC07DA152 for national stock number 5925016205008.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-620-5008.
-
MPN or Model
AM1RA3AC07DA152
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
2.50 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.940 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
2.00 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 threaded stud -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc all locations -
Circuit Protection Type
Error current all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
120.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Nontrip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
10.0 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
18.0 at 100 pct all locations -
Part Name Assigned By Controlling Agency
Hydralic magnetic circuit breaker -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unf -
Terminal Type And Quantity
2 threaded stud
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-620-5008 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM1RA3AC07DA152 | Eaton Corp |