1-321-802-5889

NSN 5950-00-295-8596

Magpot

About this product

400.0 hertz single component400.0 hertz single component400.0 hertz single component frequency rating, single phase to single phase single componentsingle phase to single phase single componentsingle phase to single phase single component input-output phase relationship, 130.0 volt-ampere single component130.0 volt-ampere single component130.0 volt-ampere single component maximum transformer power rating, inclosure type: fully enclosedfully enclosedfully enclosed.

Manufacturer part number 36761 for national stock number 5950002958596.

Datasheet

  • Product description

    Power Transformer NSN 5950-00-295-8596.

  • MPN or Model

    36761

  • Schedule B
    8504.31.4065 (Transformers, having a power handling capaci type 40 va or greater but less than 1 kva, nesoi)
  • NMF (National Motor Freight)
    063420 - Transformers, NOI, Or Transformer Par
  • Unit Weight (Est.)
    4 lb
  • Reliability Indicator
    Not establishednot establishednot established
  • Center To Center Distance Between Mounting Facilities Parallel To Length
    2.234 inches single mounting facility single center group and 2.234 inches single mounting facility single center group and 2.234 inches single mounting facility single center group and 2.266 inches single mounting facility single center group2.266 inches single mounting facility single center group2.266 inches single mounting facility single center group
  • Center To Center Distance Between Mounting Facilities Parallel To Width
    2.109 inches single mounting facility single center group and 2.109 inches single mounting facility single center group and 2.109 inches single mounting facility single center group and 2.141 inches single mounting facility single center group2.141 inches single mounting facility single center group2.141 inches single mounting facility single center group
  • Frequency Rating
    400.0 hertz single component400.0 hertz single component400.0 hertz single component
  • Input-output Phase Relationship
    Single phase to single phase single componentsingle phase to single phase single componentsingle phase to single phase single component
  • Maximum Transformer Power Rating
    130.0 volt-ampere single component130.0 volt-ampere single component130.0 volt-ampere single component
  • Body Length
    2.969 inches 2.969 inches 2.969 inches
  • Body Width
    2.781 inches 2.781 inches 2.781 inches
  • Body Height
    3.938 inches 3.938 inches 3.938 inches
  • Maximum Operating Temp
    150.0 degrees celsius150.0 degrees celsius150.0 degrees celsius
  • Inclosure Type
    Fully enclosedfully enclosedfully enclosed
  • Mounting Facility Quantity
    4 single group4 single group4 single group
  • Mounting Method
    Threaded hole single groupthreaded hole single groupthreaded hole single group
  • Winding Function And Quantity
    1 primary single component and 1 primary single component and 1 primary single component and 1 secondary single component1 secondary single component1 secondary single component
  • Thread Size
    0.164 inches single group0.164 inches single group0.164 inches single group
  • Winding Operating Current
    600.0 milliamperes ac single component single secondary
  • Winding Operating Voltage
    17.60 ac volts single component single primary and 6.30 ac volts single component single secondary6.30 ac volts single component single secondary35.00 ac volts single component single primary and 47.60 ac volts single component single primary and 127.60 ac volts single component single primary and 214.60 ac volts single component single primary and 242.60 ac volts single component single primary and 542.60 ac volts single component single primary
  • Thread Series Designator
    Unc single group
  • Terminal Type And Quantity
    11 tab, solder lug
More from these suppliers
Power Transformer

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

Mechanic Bill explains Magpot

Pricing and Availability

Get a quote for 5950-00-295-8596 power transformer
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5950002958596

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
36761 Freed Transformer Company
687007 Honeywell International Inc.
687007 Lockheed Martin Corporation
Stock Check