About this product

400.0 hertz single component frequency rating, single phase to single phase single component input-output phase relationship, 75.0 volt-ampere single component maximum transformer power rating, inclosure type: fully enclosed.

Manufacturer part number 573A499FZP3 for national stock number 5950010666332.

Datasheet

  • Product description

    Power Transformer NSN 5950-01-066-6332.

  • MPN or Model

    573A499FZP3

  • Schedule B
    8504.31.4065 (Transformers, having a power handling capaci type 40 va or greater but less than 1 kva, nesoi)
  • NMF (National Motor Freight)
    063420 - Transformers, NOI, Or Transformer Par
  • Unit Weight (Est.)
    4 lb
  • Reliability Indicator
    Not established
  • Overall Length
    3.500 inches
  • Center To Center Distance Between Mounting Facilities Parallel To Length
    2.720 inches single mounting facility single center group and 2.760 inches single mounting facility single center group
  • Center To Center Distance Between Mounting Facilities Parallel To Width
    2.220 inches single mounting facility single center group and 2.260 inches single mounting facility single center group
  • Overall Height
    4.000 inches
  • Overall Width
    3.060 inches
  • Mounting Hole Diameter
    0.215 inches single group and 0.223 inches single group
  • Frequency Rating
    400.0 hertz single component
  • Input-output Phase Relationship
    Single phase to single phase single component
  • Maximum Transformer Power Rating
    75.0 volt-ampere single component
  • Inclosure Type
    Fully enclosed
  • Mounting Facility Quantity
    4 single group
  • Mounting Method
    Bracket single group and flange single group and unthreaded hole single group
  • Winding Function And Quantity
    1 primary single component and 1 secondary single component
  • Winding Operating Current
    0.7 amperes ac single component single secondary
  • Winding Operating Voltage
    440.00 ac volts single component single primary
  • Terminal Type And Quantity
    4 wire lead
Power Transformer

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

Mechanic Bill explains Magpot

Pricing and Availability

Get a quote for 5950-01-066-6332 power transformer
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5950010666332

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
573A499FZP3 General Electric Co
9T53Y9085 General Electric Co
C15474 Electronic Transformer Corp.
177B5487PC4 General Electric Co
Stock Check