NSN 6145-00-110-2149
Electric Cable
Outer jacket colored gray.
Manufacturer part number 2SJ-12 for national stock number 6145001102149.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-110-2149.
-
MPN or Model
2SJ-12
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Cross Sectional Shape
Round -
Tempurature Rating
105.0 degrees celsius -
Cross Section Outside Diameter
0.390 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
7 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
12 awg all conductors -
Strand Awg Size Per Conductor
20 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
White 2nd position cover second conductor -
Material
Plastic polyvinyl chloride 1st position primary insulation all conductors -
Material Specification
Astm b3 assn standard single material response core conductor all conductors
More from these suppliers
- 5905-00-001-7230 MPN RNC55C1373FSFilm Fixed Resistor
- 5905-00-003-4615 MPN RNC60H1400FPFilm Fixed Resistor
- 5905-00-003-5787 MPN RWR89S1911FPInductive Wire Wound Fixed Resistor
- 5905-00-004-6085 MPN RNC60H1431FPFilm Fixed Resistor
- 5905-00-005-2497 MPN RNC55H9311FSFilm Fixed Resistor
- 5905-00-007-3867 MPN RBR55L39840BRNoninductive Wire Wound Fixed Resistor
- 5905-00-007-3870 MPN MIL-R-39005/4Noninductive Wire Wound Fixed Resistor
- 5905-00-007-7253 MPN RBR52L22100FRNoninductive Wire Wound Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-110-2149 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
2SJ-12 | Military Specifications |
MIL-C-915/60 | Military Specifications |