NSN 6145-00-112-8687
Electric Cable
Round cross sectional shape, 75.0 degrees celsius tempurature rating, 0.740 inches cross section outside diameter, conductor quantity: 1.
Manufacturer part number RHW06CF1/00SRFCLS for national stock number 6145001128687.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-112-8687.
-
MPN or Model
RHW06CF1/00SRFCLS
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Cross Sectional Shape
Round -
Tempurature Rating
75.0 degrees celsius -
Cross Section Outside Diameter
0.740 inches -
Conductor Quantity
1 -
Strand Quantity Per Conductor
19 single conductor -
Conductor Form
Stranded single conductor -
Round Conductor Size
00 awg single conductor -
Strand Awg Size Per Conductor
12 single conductor -
Voltage Rating
600.0 root mean square (rms) operating voltage single conductor -
Material
Copper core conductor all conductors -
Material Specification
Qq-w-343, soft federal specification single material response core conductor all conductors -
Surface Treatment
Tin core conductor single conductor
More from these suppliers
- 5975-00-194-8879 MPN A-A-59214-2-D-20Junction Box
- 5975-00-578-9364 MPN A-A-50552Electrical Box Connector
- 5940-00-926-9869 MPN A-A-59126/18Stud Terminal
- 5940-01-298-4628 MPN AA59126/1110Stud Terminal
- 5975-01-375-2392 MPN AA50553-12L201SElectrical Box Connector
- 5940-01-536-3383 MPN AA59125/2-38TB8BTerminal Board
- 5950-01-567-2723 MPN A-A-59699Radio Frequency Coil
- 5940-01-602-8766 MPN A-A-59126/20-03Stud Terminal
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-112-8687 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
RHW06CF1/00SRFCLS | Federal Commercial Item Description |
A-A-59544 | Federal Commercial Item Description |
J-C-30 | Federal Specifications |