NSN 6145-00-117-8850
Electric Cable
Round cross sectional shape, 60.0 degrees celsius tempurature rating, 0.375 inches cross section outside diameter, conductor quantity: 3.
Manufacturer part number UL 62 for national stock number 6145001178850.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-117-8850.
-
MPN or Model
UL 62
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Round -
Tempurature Rating
60.0 degrees celsius -
Cross Section Outside Diameter
0.375 inches -
Conductor Quantity
3 -
Strand Quantity Per Conductor
26 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
3 singles -
Voltage Rating
300.0 root mean square (rms) operating voltage all conductors -
Material
Plastic 1st position primary insulation all conductors -
Material Specification
Qq-w-343, soft federal specification single material response core conductor all conductors
More from these suppliers
- 6145-00-959-4489 MPN UL62SVT3BCK3/18TPETPEElectrical Power Cable
- 4820-00-287-4376 MPN WWV51Check Valve
- 5975-00-681-4255 MPN WC586Conduit Outlet
- 5975-01-032-4632 MPN WW-C-581Rigid Metal Conduit
- 5935-01-231-9637 MPN WC596/42-3Electrical Plug Connector
- 5305-00-010-2820 MPN FF-S-210Setscrew
- 5305-00-011-2865 MPN FFS92TYPE1STYLE1SMachine Screw
- 5305-00-012-0706 MPN FFS85TYPE2STYLE10PHexagon Head Cap Screw
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
![Mechanic Bill explains Electric Cable](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 6145-00-117-8850 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UL 62 | Underwriters Laboratories Inc. |
JC580SJT3CF3/16TTJ | Federal Specifications |
UL62SJT2BCF3/16PVCPVC | Underwriters Laboratories Inc. |
J-C-580 | Federal Specifications |
J-C-580SJT3CF3/16TTJ | Military Specifications |
UL62SJT3BCF3/16PVCPVC | Underwriters Laboratories Inc. |
Stock Check
![](/public/images/partscage_shelf3.png)