NSN 6145-00-160-2012
Electric Cable
Round cross sectional shape, 200.0 degrees celsius tempurature rating, 0.220 inches cross section outside diameter, conductor quantity: 2.
Manufacturer part number 710842-3 for national stock number 6145001602012.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-160-2012.
-
MPN or Model
710842-3
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Round -
Tempurature Rating
200.0 degrees celsius -
Cross Section Outside Diameter
0.220 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
16 awg all conductors -
Strand Awg Size Per Conductor
29 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
White core conductor first conductor -
Material
Plastic polytetrafluoroethylene 1st position primary insulation all conductors -
Material Specification
Qq-w-343, soft federal specification single material response core conductor all conductors
More from these suppliers
- 5945-00-062-3317 MPN 719042-3REVBElectromagnetic Relay
- 5905-00-226-4744 MPN 5200-490Inductive Wire Wound Fixed Resistor
- 5905-00-240-2726 MPN 4171590-796Film Fixed Resistor
- 5905-00-279-1886 MPN 4171300-234Composition Fixed Resistor
- 5905-00-288-8771 MPN 4171595-555Film Fixed Resistor
- 5905-00-429-4116 MPN 5039-671Inductive Wire Wound Fixed Resistor
- 5905-00-490-3937 MPN 713128-4Nonprecision Wire Wound Variable Resistor
- 5930-00-677-8241 MPN 721899-214Rotary Switch
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-160-2012 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
710842-3 | National Wire And Cable Corporation |
710842-3 | Raytheon Company |