NSN 6145-00-174-3581
Electric Cable
Round cross sectional shape, 0.254 inches cross section outside diameter, 3 conductors, strand quantity per conductor: 19 all conductors.
Manufacturer part number 3SJ-18 for national stock number 6145001743581.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-174-3581.
-
MPN or Model
3SJ-18
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.1 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
0.254 inches -
Conductor Quantity
3 -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
3 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Material
Tin 2nd position coating cable -
Material Specification
Astm b3 assn standard single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors -
Surface Treatment Specification
Astm b33-63 assn standard single treatment response core conductor all conductors
More from these suppliers
- 5905-00-004-0198 MPN RNC50H1431FMFilm Fixed Resistor
- 5905-00-005-2677 MPN RER65FR133PInductive Wire Wound Fixed Resistor
- 5905-00-005-2867 MPN RC42BF153KComposition Fixed Resistor
- 5905-00-006-5506 MPN MIL-R-39007/6Inductive Wire Wound Fixed Resistor
- 5905-00-007-3860 MPN RLR20C1600GMFilm Fixed Resistor
- 5905-00-008-8354 MPN MILR55182-3Film Fixed Resistor
- 5905-00-011-4586 MPN MILR26-2Inductive Wire Wound Fixed Resistor
- 5905-00-018-0950 MPN RW23V301Inductive Wire Wound Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-174-3581 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
3SJ-18 | Military Specifications |
MIL-C-915/60 | Military Specifications |