NSN 6145-00-224-1721
Electric Cable
Round cross sectional shape, 0.595 inches cross section outside diameter, 2 conductors, strand quantity per conductor: 19 all conductors.
Manufacturer part number MILC16839 for national stock number 6145002241721.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-224-1721.
-
MPN or Model
MILC16839
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.2 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
0.595 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
19 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
10 awg all conductors -
Strand Awg Size Per Conductor
22 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
600.0 ac rated working voltage all conductors -
Material
Copper core conductor all conductors -
Material Specification
Qq-w-343 federal specification single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors
More from these suppliers
- 5950-00-056-8284 MPN 1559546Power Transformer
- 5935-00-061-6101 MPN 59A5A222-1Electrical Receptacle Connector
- 5905-00-100-4290 MPN 12Z13110-8017Inductive Wire Wound Fixed Resistor
- 5985-00-102-4198 MPN 2515571-1Waveguide Switch
- 5940-00-238-9612 MPN 1112945-1Lug Terminal
- 4820-00-379-6177 MPN 511932PC4Globe Valve
- 4920-00-404-5239 MPN 64A15F1001-2Stores Management System Test Set
- 5935-00-498-3456 MPN 2686360-00Electrical Receptacle Connector
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-224-1721 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
MILC16839 | Military Specifications |
MILC16839TYPEDPU10 | Military Specifications |
15C12151-1500 | Navair And Navsea Managed |