NSN 6145-00-284-0576
Electric Cable
Round cross sectional shape, -40.0 degrees celsius and 75.0 degrees celsius tempurature rating, 0.640 inches cross section outside diameter, conductor quantity: 2.
Manufacturer part number M3432-02HOF (2/10) 0640 for national stock number 6145002840576.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-284-0576.
-
MPN or Model
M3432-02HOF (2/10) 0640
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.2 lb -
Cross Sectional Shape
Round -
Tempurature Rating
-40.0 degrees celsius and 75.0 degrees celsius -
Cross Section Outside Diameter
0.640 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
104 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
10 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
White 2nd position cover second conductor -
Material
Rubber chloroprene class cr 1st position jacket cable -
Material Specification
Qq-w-343, soft federal specification single material response core conductor all conductors -
Surface Treatment
Tin core conductor all conductors -
Surface Treatment Specification
Astm b33-63 assn standard single treatment response core conductor all conductors
More from these suppliers
- 4820-01-194-6793 MPN 538D7525 PIECE 12Globe Valve
- 4820-01-377-4051 MPN 184-3001-209Ball Valve
- 5905-00-721-3677 MPN RNC55H1371FSFilm Fixed Resistor
- 6145-00-524-9130 MPN UL 62Electrical Wire
- 5905-00-001-5835 MPN RNC60K26R7FPFilm Fixed Resistor
- 5905-00-001-7185 MPN MILR22-10Nonprecision Wire Wound Variable Resistor
- 5905-00-001-7330 MPN RBR56L20501BPNoninductive Wire Wound Fixed Resistor
- 5905-00-004-6052 MPN RER60F1250MInductive Wire Wound Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-284-0576 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M3432-02HOF (2/10) 0640 | Military Specifications |
MIL-DTL-3432 | Military Specifications |
120-07639-6 | Aqua-chem Inc. |
S0 | Underwriters Laboratories Inc. |
MIL-C-3432 | Military Specifications |
CO-02HOF(2/10)0640 | Military Specifications |