NSN 6145-00-295-0855
Electric Cable
Round cross sectional shape, 60.0 degrees celsius tempurature rating, 0.670 inches cross section outside diameter, conductor quantity: 3.
Manufacturer part number 10AWGP0RTABLEC0RD for national stock number 6145002950855.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-295-0855.
-
MPN or Model
10AWGP0RTABLEC0RD
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.2 lb -
Cross Sectional Shape
Round -
Tempurature Rating
60.0 degrees celsius -
Cross Section Outside Diameter
0.670 inches -
Conductor Quantity
3 -
Strand Quantity Per Conductor
105 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
10 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
3 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
Green 1st position primary insulation third conductor -
Material
Rubber natural or rubber synthetic 1st position primary insulation all conductors
More from these suppliers
- 6145-00-003-0729 MPN HP3-ETXBGE8Electrical Wire
- 6145-01-056-5515 MPN NEMA WC 27500Electrical Power Cable
- 6145-01-118-8917 MPN M27500-24NA3S12Electrical Special Purpose Cable
- 6145-01-141-6809 MPN NEMA MW1000Electrical Wire
- 6145-01-307-7950 MPN HP4-KK-RLB0Electrical Wire
- 6145-01-360-5863 MPN NEMA WC27500Electrical Special Purpose Cable
- 6145-01-419-8394 MPN M27500B20WP3U00Electrical Special Purpose Cable
- 6145-01-570-7401 MPN M27500-20RA4U00Electrical Special Purpose Cable
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-295-0855 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
10AWGP0RTABLEC0RD | General Electric Co |
UL 62 | National Electrical Mfrs Assn |
19205 | Belden Wire & Cable Company Llc |
01524 | Belden Canada Inc |
6000-8006-165 | Rex Systems Incorporated |
T-32196 | Tyco Electronics Integrated Cable |
5010/3 | Universal Wire And Cable Co |
572-0162-014 | Boeing Company, The |
110189-405 | Harris Corporation |
1938/3 | Alpha Wire Corporation |
SI53158-3-10 | General Electric Co |
SI53158-3-10 | General Electric Co |
1900440 | General Motors Corp |
3125734 | Whitney Blake Company |
3913 | General Cable Industries Inc |
1963/3 | Alpha Wire Corporation |
UL62S00W6BCK3/10EPCPE | National Electrical Mfrs Assn |
J-C-580 | Federal Specifications |
J-C-580SO6CK3/10SRNJ | Federal Specifications |
020102 | Ikon Systems Inc |
M2783 | Manhattan Electric Cable Corp |