NSN 6145-00-334-8635
Electric Cable
Round cross sectional shape, 60.0 degrees celsius tempurature rating, 0.635 inches cross section outside diameter, conductor quantity: 3.
Manufacturer part number UL 62 for national stock number 6145003348635.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-334-8635.
-
MPN or Model
UL 62
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.3 lb -
Cross Sectional Shape
Round -
Tempurature Rating
60.0 degrees celsius -
Cross Section Outside Diameter
0.635 inches -
Conductor Quantity
3 -
Strand Quantity Per Conductor
65 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
12 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
3 singles -
Voltage Rating
600.0 ac rated working voltage all conductors -
Color
Green 3rd position cover third conductor -
Material
Rubber natural 1st position primary insulation all conductors -
Material Specification
Mil-i-3930, type is military specification single material response 1st position primary insulation all conductors -
Surface Treatment
Tin core conductor all conductors -
Nondefinitive Specification/std Data
So type
More from these suppliers
- 4820-00-287-3097 MPN WWV51Check Valve
- 5975-01-032-4638 MPN WW-C-581Rigid Metal Conduit
- 5930-00-189-0635 MPN 3-30ACLASS3DESIGNAToggle Switch
- 4820-00-826-9949 MPN WWV54Gate Valve
- 5905-01-362-6971 MPN MIL-R-55342/7Film Fixed Resistor
- 5935-01-231-9637 MPN WC596/42-3Electrical Plug Connector
- 5925-01-128-4368 MPN WC375/15-013Circuit Breaker
- 5305-00-010-1193 MPN FF-S-92B TY I ST 2SMachine Screw
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-334-8635 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UL 62 | Underwriters Laboratories Inc. |
JC580 | Federal Specifications |
UL62SOOW6BCK3/12EPCPE | Underwriters Laboratories Inc. |